| Customization: | Available |
|---|---|
| Breaking Capacity: | High Voltage Circuit Breakers |
| Operation: | Manual Type |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

No. | Item | Unit | Technical Parameters | ||
1 | Rated Voltage | kV | 40.5 | ||
2 | Rated Frequency | Hz | 50/60 | ||
3 | 1min Power Frequency Withstand Voltage | Alternating, relatively low | kV | 95 | |
Broken | 118 | ||||
Lightning Impulse Withstand Voltage (Peak) | Alternating, relatively low | 185 | |||
Broken | 215 | ||||
4 | Rated Current | A | 1250, 1600, 2000, 2500, 3150 | ||
5 | Rated Short-Time Withstand Current (RMS) | kA | 25 | 31.5 | |
6 | Rated Peak Withstand Current | kA | 63 | 80 | |
7 | Rated Short-Circuit Breaking Current (RMS) | kA | 25 | 31.5 | |
8 | Rated Short-Circuit Making Current (Peak) | kA | 63 | 80 | |
9 | Rated Duration Of Short-Circuits | s | 4 | ||
10 | Rated Sequence Of Operation | - | O—0.3s—CO—180s—CO | ||
11 | Rated Single Phase-to-Ground Fault Breaking Current | kA | 21.7 | 27.4 | |
12 | Rated Cable Charging Current Switching Test | A | 50 | ||
13 | Rated Breaking Current of Single/Back-to-Back Capacitor Bank | A | ≥800 / 800 | ||
14 | Mechanical Endurance | Times | 10000 | ||
15 | Short-Circuit Current Breaking Times | Times | 20 | ||
16 | 1min Power Frequency Withstand Voltage of Secondary Circuit | V | 2000 | ||
17 | Rated Operating Voltage | Closing line circle | V | DC110/220, AC220 | |
Opening line circle | DC110/220, AC220 | ||||
18 | Rated Voltage of Energy Storage Motor | V | DC110/220, AC220 | ||
19 | Rated Power of Energy Storage Motor | W | 250 | ||
20 | Energy Storage Time (At Rated Voltage) | s | ≤10 | ||
21 | Rated SF6 Gas Pressure (Gauge Pressure at 20℃) | MPa | 0.35+0.02/0 | ||
22 | Alarm Pressure | MPa | 0.30±0.01 | ||
23 | Minimum Functional Pressure (Lockout Pressure) | MPa | 0.28±0.01 | ||
24 | Annual Leakage Rate | % | ≤0.5 | ||
25 | Gas Moisture Content | μL/L | ≤150 | ||
26 | Moving Contact Stroke | mm | ≥78 | ||
27 | Contact Opening Distance | mm | ≥50 | ||
28 | Opening Time | ms | 33~130 | ||
29 | Closing Time | ms | 65~95 | ||
30 | Three-Phase Asynchronism of Closing & Opening | ms | ≤2 | ||
31 | Average Opening Speed (Within 10ms after Half Stroke) | m/s | 2.2~2.8 | ||
32 | Average Closing Speed (Within 10ms after Half Stroke) | m/s | ≥1.5 | ||
33 | Main Circuit Resistance | μΩ | ≤32 (Trolley Type) | ≤25 (Fixed Type) | |